Eight types of air compressor failures and solutions that customers don't understand

According to air compressor engineers, the most common daily maintenance is often some basic maintenance. Sometimes, they even travel thousands of miles to the customer's place just to easily replace a component. This not only wastes money for the customer, but also delays work. Here, based on the descriptions of many air compressor engineers, the editor summarizes the eight common daily failures and basic maintenance solutions as follows:


1. The air compressor cannot start

First check whether there is a control voltage. If not, check whether the fuse is intact; if there is a control voltage, check whether the control relay and time relay are operating normally.


2. The air compressor does not start smoothly

The machine automatically stops after a few seconds of startup. Check the electrical aspects, such as whether the automatic air switch is tripped, whether the voltage is normal, whether the closing degree of the air intake butterfly valve is normal (the compressor cannot be started with load), and whether the contactor and the three phases of the motor are normal during Y-△ starting, etc.


3. The air compressor does not supply air

Check whether the control cylinder is moving. If it is moving, check whether the butterfly valve has mechanical faults; if there is no fault, check whether the loading electromagnetic ISV coil has suction; after eliminating the mechanical faults and coil faults of the ISV electromagnetic valve, check the sub-circuit where the electromagnetic valve ISV is located one by one.


4. The exhaust pressure of the air compressor is too low

First, check the pressure before and after separation, whether the manual valve and the regulating electromagnetic valve 2SV are leaking; then check whether there is leakage in the air pipeline, whether the butterfly valve is fully open, whether the air intake regulator is working properly, whether the electromagnetic valve 3SV and 8SV are leaking, whether the pressure switch IPS needs to be readjusted, etc.


5. The air compressor stops due to oil injection at the inlet

First check whether the oil cut-off electromagnetic valve 5SV has voltage and whether the mechanical part is normal; if it is normal, check the check valve and reassemble or replace it.


6. The exhaust temperature of the air compressor is too high. The exhaust temperature is generally between 80 and 95°C. If there is not enough lubricating oil cooling, the temperature will be too high and cause failure. First, check whether the ambient temperature, compressor lubricating oil, oil level, oil quality, cooling fan, etc. are normal; then check whether the oil cooler and aftercooler are clean, whether the temperature control valve element, oil cut-off solenoid valve voltage and valve body are normal. If the diaphragm is damaged or the temperature control valve core does not work, it needs to be replaced; then check whether the oil filter is dirty or needs to be replaced.


7. High oil consumption of air compressor

Check whether the oil content of the condensate discharged by the steam trap is too high, whether the compressor oil level is high, whether the opening pressure of the small pressure valve is normal, whether the return oil pipe is blocked, whether the oil separation core is blocked, etc. The above problems will affect the oil consumption and should be handled in time.


8. Automatic shutdown during air compressor operation

First, check whether the machine is normal and automatically shut down; then check whether the automatic switch and thermal relay are in action, whether it causes the cooling fan motor to stop, or the exhaust temperature is too high, or the pressure is too high, etc., and whether the motor voltage is normal.